2024-03-08 Release Note

The update for Hyper Lab on March 8, 2024, has been completed.

Hyper Lab Version : 2024.03.08


Changelogs

1. User Fields newly added

In the Molecule list of My bench, a new type of 'User fields' has been added, allowing users to create their fields to edit and manage data.

User fields, like the existing fields provided, can be sorted, filtered, and viewed in the same manner.

(1) Creating a New Field

User fields can be managed from the right-side screen that opens when you click the 'Field' button at the top of the Molecule list.

At the bottom of the right-side screen, you can create a new user field by clicking the 'Create a new field' button.

  • Enter the name for the new field and select the type of field to add it to the Molecule list.

  • Each field name must be unique and cannot be duplicated.

  • The field type can be selected from text, number, or tag only. (Expansion of types to be provided later is planned.)

(2) User Field Editing

Users can edit and manage the fields they have created.

The methods to enter the field editing screen are as follows:

  • Method 1) Clicking the [More (…)] button on the user field added to the Molecule list and then clicking [Edit field] will open the field editing screen on the right.

  • Method 2) Clicking on a user field in the right screen that opens after clicking the [Fields] button at the top of the Molecule list will switch to the field editing screen.

In field editing, you can change the field's name, change the type of the field, and delete the field.

[Changing Field Type]

The type of the field can only be changed to a type that is possible to switch from the existing type.

  • Text type field → Can only be changed to numeric type

    • If the original field contains a mix of numeric data and text data, conversion is not possible.

  • Number type field → Can only be changed to text type

  • Tag type field → Can only be changed to text type

[Deleting Field]

Fields can be deleted using the [Delete Field] button located at the bottom of the field editing screen.

If a field is deleted, all data stored in that field will also be deleted.


2. 3D Viewer Improvements

The 3D Viewer has been enhanced to allow for the use of a wider range of features.

(1) Addition of 2D Diagram

In the 3D Viewer, the 2D Diagram has been improved to allow viewing of interactions in a 2D structure as well.

  • Each interaction is displayed differently based on the settings in the existing control panels on the left and right.

  • By clicking the Pin icon at the top right of the 2D Diagram, you can control the display of indexes for each type of interaction.

(2) Viewer Setting Enhancement

The settings of the 3D Viewer have been refined to enable more detailed analysis.

[Binding Pocket Display]

[Interaction Entities]

In the 3D View and 2D Diagram, you can set the following major interaction categories.

  • Receptor-Ligand

  • Ligand-Ligand

  • Receptor-Receptor

  • Ligand-Water

  • Receptor-Water

[Interaction Types]

The types of interactions that can be observed in the 3D View and 2D Diagram are as follows.

[Binding Pocket Residues]

[Protein]

[Ligand]

(3) Ligand Display Function Added

A function has been added to the Ligand Display panel, located on the right side of the Viewer, allowing you to set colors for each of the conformers.

(4) Viewer Screenshot Function Added

By clicking the [Screenshot] button on the top left of the Viewer, you can obtain the current view of the Viewer as a PNG file.

The files are provided separately for the 3D Viewer and the 2D Diagram.


Bug fix

Bug fixes and stability improvements have been made.

Last updated